From aa886edc34ba9f8cb9162be46e5e731f9b2c8f24 Mon Sep 17 00:00:00 2001 From: alex Date: Wed, 29 Jul 2026 11:59:23 -0600 Subject: [PATCH] Polishing order --- INL_Talk.tex | 101 ++++++++++++++++++++++++++++++++++++++------------- 1 file changed, 75 insertions(+), 26 deletions(-) diff --git a/INL_Talk.tex b/INL_Talk.tex index 53fecf3..bdb72a7 100644 --- a/INL_Talk.tex +++ b/INL_Talk.tex @@ -74,7 +74,6 @@ Provide applied economic insight to support decision-making across Wyoming. The \begin{itemize} \item Over 65 projects \item Nuclear sector analysis - \item IMPLAN, REMI, and econometrics \item Energy and policy analysis \end{itemize} @@ -107,12 +106,18 @@ Economic Modeling Tools \end{frame} %%%%%%%%%%%%% \begin{frame}{Regional Economic Models, Inc\. (Augmented I-O)} - \includegraphics[width=\textwidth]{Economic-Impacts-of-Data-Centers} + \href{https://urldefense.com/v3/__https:/www.remi.com/events/analysis-of-data-centers__;!!KupS4sW4BlfImQPd!Mwt-ArdkBfD0TqUmnE8uV1N1XTzXJLy4iaVpcOsYkn7OEJX8lgKw6J_AnEvMFvn_DGu6FZeOxFp0SoTGJMOkqA$}{\includegraphics[width=\textwidth]{Economic-Impacts-of-Data-Centers}} \end{frame} %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% -\section{Background} +\section{Project Background} +\begin{frame}[plain] + \centering + \huge +Project Background +\end{frame} + %%%%%%%%%%%%%%%%%%%%%%%%%%%% \begin{frame}{About Wyoming} \begin{columns} @@ -233,7 +238,6 @@ Economic Modeling Tools \end{frame} %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% -\section{Economic Impact} \begin{frame}{Economic Impact Advantages} Input output model challenges \begin{columns} @@ -271,7 +275,8 @@ Input output model challenges %\end{columns} % %\end{frame} -\section{Wyoming Nuclear} +\section{Model of Wyoming Nuclear Reactors} + \begin{frame}[plain] \centering \huge @@ -331,7 +336,7 @@ Electricity and Reactors \includegraphics[width=0.8\textwidth]{EIA_Additions} \end{frame} %%%%%%%%%%%%%% -\section{Input Output of a Reactor} +%\section{Input Output of a Reactor} \begin{frame}{Input Output Model of Nuclear Growth} \vfill \only<1-8>{ @@ -376,17 +381,77 @@ Electricity and Reactors \includegraphics[width=0.9\textwidth]{Single_Reactor_Taxes} \end{frame} %%%%%%%%%%%% -\section{Time Considerations} +%\section{Time Considerations} \begin{frame}{Accounting for Time with Single Reactor} \includegraphics[width=\textwidth]{NPV_Table} \end{frame} -\begin{frame}{Accounting for Time with Multiple Reactors} +\begin{frame}{Accounting for Timing of Multiple Reactors} \includegraphics[width=\textwidth]{Reactor_Probability} \end{frame} -\section{Model Results} \begin{frame}{Results} \includegraphics[width=\textwidth]{Results} \end{frame} +%%%%%%%%%%%%%%%% +\section{Model of Data Center} +\begin{frame}[plain] + \centering + \huge +Data Centers and Nuclear +\end{frame} +%%%%%%%%%% +\begin{frame}{Data Center Addition} + \begin{itemize} + \item<1-> Nuclear rector added in Lincoln County + \item<2-> Reactor addition leads to data center (exogenous) + \item<3-> Nuclear provides extra value to data centers + \item<4->Don't double count if I-O includes data centers + \end{itemize} + +\includegraphics[width=\textwidth]{Utah_Data_Center_Panorama_(cropped)} +\end{frame} +%%%%%%%%%% +\begin{frame}{Why REMI?} + \centering + \textbf{Augmented I-O selected} + \begin{itemize} + \item<2-> Rapidly changing industry + \item<3-> Coefficients limit growth in future + \item<4-> Energy demand equations + \end{itemize} +\end{frame} +\begin{frame}{Preparing the Data: Peak Construction Employment by Capacity} + \centering + \includegraphics[width=0.8\textwidth]{Peak_Construction_Employment_Fit} +\end{frame} + +\begin{frame}{Preparing the Data: Operating Employment by Capacity} +\centering + \includegraphics[width=0.9\textwidth]{Operating_Employment_Fit} +\end{frame} +\begin{frame}{REMI Model} + \includegraphics[width=\textwidth]{Custom_Industry} + \includegraphics[width=0.7\textwidth]{Employment_Event} +\end{frame} +\begin{frame}{REMI GDP Results} + \centering + \includegraphics[width=0.8\textwidth]{GDP_Region_Plot} +\end{frame} +\begin{frame}{REMI GDP Sub-Regions} + \centering + \includegraphics[width=0.8\textwidth]{GDP_Other_Counties} +\end{frame} +\begin{frame}{REMI Job Mix} + \centering + \includegraphics[width=0.6\textwidth]{Job_Facet_Plot} +\end{frame} +%%%%%%%%%%%% +\section{Other Industries} +\begin{frame}[plain] + \centering + \huge + Considering Other Nuclear Sectors +\end{frame} + \begin{frame}{Considering Downstream Effects} The I-O model applies existing regional production. That may not always apply to nuclear sectors. \vfill @@ -411,23 +476,7 @@ Electricity and Reactors \end{columns} \end{frame} -%%%%%%%%%% -\begin{frame}{REMI Model} - \includegraphics[width=\textwidth]{Custom_Industry} - \includegraphics[width=0.7\textwidth]{Employment_Event} -\end{frame} -\begin{frame}{REMI GDP Results} - \centering - \includegraphics[width=0.8\textwidth]{GDP_Region_Plot} -\end{frame} -\begin{frame}{REMI GDP Sub-Regions} - \centering - \includegraphics[width=0.8\textwidth]{GDP_Other_Counties} -\end{frame} -\begin{frame}{REMI Job Mix} - \centering - \includegraphics[width=0.6\textwidth]{Job_Facet_Plot} -\end{frame} + %%%%%%%%%%%%%%%%% \begin{frame}[plain]